    All electrical appliances applying mains voltage have to present at minimum 2 stages of protection to the person. This is to guarantee that if just one of the defense levels have been to fail, there is the again-up of the second layer nevertheless in position. This can make electrical tools quite risk-free to use. Appliances can be Course one or Course two.

    When PAT screening, it is critical to to start with identify the Course of the equipment as Class one appliances are examined in different ways from Course two appliances.

    Based on how exactly the protection is presented, electrical equipment are put into five Lessons of tools construction which are Class 1, two, three, , 01. Of these the most important are Course 1 & two. For completeness all the Lessons are explained under.

    Class one

    In this article the security is supplied by a combination of insulation and use of the mains Earth. It is very best shown by referring to an electrical fireplace that has been taken apart.

    In the open up plug the 3 wires connecting to the Dwell, NEUTRAL and EARTH pins. Inside of the fireplace, the brown Live wire and the blue NEUTRAL wire connect to a plastic connector. The environmentally friendly/yellow Earth wire connects to the steel scenario of the fire.

    The person is guarded from electrical shock by the plastic insulation of the connector. This retains the Are living and NEUTRAL wires in position and helps prevent them from touching the metal case of this electric hearth. This plastic insulation of the connector is recognized as basic insulation.

    If this simple insulation ended up to fall short, say thanks to too much motion of the cable where by it touches the steel case then the user of the fire can acquire an electric powered shock if not for the truth that the EARTH wire is present.

    By connecting to the metallic case of the electrical hearth, the EARTH wire retains all this metallic at EARTH possible. What this usually means is that it is not possible to get an electrical shock even when the metal scenario of the fire is connected straight to the Live voltage. In apply a fuse would blow either in the plug or the principal fuse box to safeguard the user.

    In summary, in Course 1 appliances the person is secured by a combination of basic insulation and the provision of an EARTH relationship, so furnishing two ranges of safety.

    When PAT Tests Course one appliances, the Earth Continuity and Insulation Resistance tests are carried out.

    Class two

    In a Class two equipment, the consumer is secured by at least two levels of insulation. For this cause, Class two appliances are also identified as Double Insulated. They do not demand an Earth link.

    This is best proven by seeking inside of a Course two electric powered drill which has been opened up. Inside a single can see that as very well as the plastic connector furnishing standard insulation, there is extra insulation delivered by the plastic enclosure of the drill.

    The user is hence guarded by two different levels of insulation. When PAT testing Class 2 appliances, just the Insulation Resistance examination is carried out.

    Course two appliances are often indicated by the double box symbol on the rating plate.

    Class three

    Gear built to Class 3 conventional are created to be equipped from a special protection isolating transformer whose output is recognised as Protection Extra-Lower Voltage or SELV. This should not exceed 50 V AC and is normally is down below 24V or 12V. All Course 3 appliances are marked by a special image. There is no use of an Earth in Class III appliance

    The electrical basic safety of Course 3 appliances are taken treatment of in the basic safety isolating transformer design and style wherever the separation concerning the windings is equal to double insulation. The transformer is marked as being suited for use with Class III appliances.

    Class & 01

    This variety of equipment is not for standard use in business enterprise or residential environments. It is just offered listed here for completeness.

    Course appliances rely only on standard insulation for defense from electric powered shock. For this explanation, they do not have two amounts of defense built in and are not permitted for sale. The brass lamp shown below is an example of a two wire, steel cased appliance with only simple insulation. There is no provision for relationship of an earth to the bulb holder.

    In Course 01 appliances, there is provision for an Earth relationship, but it is wired with both twin main cable or only has a two-pin plug, so an Earth are not able to be linked. AS in Course tools, a person is dependent only on primary insulation for defense from electric shock. As they only have 1 amount of protection, Class 01 appliances are not permitted for sale.

    If in the course of PAT tests one will come across a Course or Class 01 appliance these can be unsuccessful.

    Identifying Course I & Course II Equipment

    As the PAT tests carried on Course 1 and Course 2 appliances vary, it is essential to recognize a single from the other. There is no other location of PAT testing that causes more confusion than this and there are lots of myths encompassing this. It will be useful to record some of these.

    If there is a fuse in the plug, then it must be Course one.

    It is made of metal so it ought to be Class 1

    The situation is plastic so it must be Course two

    It has a three main cable so it ought to be Class one

    The plug has a metal Earth pin so it need to be Course 1

    None of the previously mentioned statements is a fool-proof way to recognize Class I and Class II appliances and some are pretty deceptive.

    The most straightforward rule to utilize is the a single below.

    If the ranking plate has a double box then the appliance is Class two. If it does not then it is Class 1.

    Illustration - Kettle

    The ranking plate on this kettle clearly has no "double-box" image, so employing our rule, it need to be Class 1. The Earth relationship from the plug is terminated on the outside the house metallic casing of the heating aspect. When PAT testing this kettle the Earth Continuity and Insulation Resistance exam has to be carried out.

    Illustration - Plug-top rated power source

    The ranking plate on this Plug-best transformer clearly reveals the "double box" symbol, so this is a Class 2 appliance. Observe that it has a plastic Earth pin, as this is not needed for Course II. http://villanyszerelesbudapest.simpsite.nl/ (Not all Class 2 appliances have a plastic earth pin). Just the Insulation Resistance examination has to be carried out for the duration of PAT screening.

    Case in point - Mains extension

    The score plate on this extension is moulded in the plastic. It obviously does not have a "double-box" image, so it have to be a Class one. When PAT testing this extension guide the Earth Continuity and Insulation Resistance test has to be carried out.

    Example - Table lamp

    The score plate on this table lamp evidently exhibits the "double-box" so it is a Course 2 appliance. (Observe that this is a Course 2 appliance that is mostly in a metallic enclosure). The bulb holder is designed of plastic and presents the needed double insulation. Just the Insulation Resistance exam has to be carried out during PAT testing.